Instytut Podstawowych Problemów Techniki
Polskiej Akademii Nauk

Partnerzy

W. Białobrzeska


Ostatnie publikacje
1.  Białobrzeska W., Firganek D., Czerkies M., Lipniacki T., Skwarecka M., Dziąbowska K., Cebula Z., Malinowska N., Bigus D., Bięga E., Pyrć K., Pala K., Żołędowska S., Nidzworski D., Electrochemical immunosensors based on screen-printed gold and glassy carbon electrodes: comparison of performance for respiratory syncytial virus detection, Biosensors, ISSN: 2079-6374, DOI: 10.3390/bios10110175, Vol.10, No.11, pp.175-1-13, 2020

Streszczenie:
This paper presents the development and comparison of label-free electrochemical immunosensors based on screen-printed gold and glassy carbon (GC) disc electrodes for efficient and rapid detection of respiratory syncytial virus (RSV). Briefly, the antibody specific to the F protein of RSV was successfully immobilized on modified electrodes. Antibody coupling on the Au surface was conducted via 4-aminothiophenol (4-ATP) and glutaraldehyde (GA). The GC surface was modified with poly-L-lysine (PLL) for direct anti-RSV conjugation after EDC/NHS (1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide/N-Hydroxysuccinimide) activation. Electrochemical characterizations of the immunosensors were carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). GC-based immunosensors show a dynamic range of antigen detection from 1.0 × 10^5 PFU/mL to 1.5×10^7 PFU/mL, more than 1.0 × 10^5 PFU/mL to 1.0 × 10^7 PFU/mL for the Au-based sensor. However, the GC platform is less sensitive and shows a higher detection limit (LOD) for RSV. The limit of detection of the Au immunosensor is 1.1 × 10^3 PFU/mL, three orders of magnitude lower than 2.85 × 10^6 PFU/mL for GC. Thus, the Au-based immunosensor has better analytical performance for virus detection than a carbon-based platform due to high sensitivity and very low RSV detection, obtained with good reproducibility.

Słowa kluczowe:
respiratory syncytial virus, cyclic voltammetry, electrochemical impedance spectroscopy, sensor, gold electrode, glassy carbon

Afiliacje autorów:
Białobrzeska W. - inna afiliacja
Firganek D. - inna afiliacja
Czerkies M. - IPPT PAN
Lipniacki T. - IPPT PAN
Skwarecka M. - inna afiliacja
Dziąbowska K. - inna afiliacja
Cebula Z. - inna afiliacja
Malinowska N. - inna afiliacja
Bigus D. - inna afiliacja
Bięga E. - inna afiliacja
Pyrć K. - inna afiliacja
Pala K. - inna afiliacja
Żołędowska S. - inna afiliacja
Nidzworski D. - inna afiliacja
70p.

Kategoria A Plus

IPPT PAN

logo ippt            ul. Pawińskiego 5B, 02-106 Warszawa
  +48 22 826 12 81 (centrala)
  +48 22 826 98 15
 

Znajdź nas

mapka
© Instytut Podstawowych Problemów Techniki Polskiej Akademii Nauk 2024