Instytut Podstawowych Problemów Techniki
Polskiej Akademii Nauk

Partnerzy

Małgorzata Gazińska


Ostatnie publikacje
1.  Zargarian S., Rinoldi C., Ziai Y., Zakrzewska A., Fiorelli R., Gazińska M., Marinelli M., Majkowska M., Hottowy P., Mindur B., Czajkowski R., Kublik E., Nakielski P., Lanzi M., Kaczmarek L., Pierini F., Chronic Probing of Deep Brain Neuronal Activity Using Nanofibrous Smart Conducting Hydrogel-Based Brain–Machine Interface Probes, Small Science, ISSN: 2688-4046, DOI: 10.1002/smsc.202400463, pp.2400463-1-19, 2025

Streszczenie:
The mechanical mismatch between microelectrode of brain–machine interfaces (BMIs) and soft brain tissue during electrophysiological investigations leads to inflammation, glial scarring, and compromising performance. Herein, a nanostructured, stimuli-responsive, conductive, and semi-interpenetrating polymer network hydrogel-based coated BMIs probe is introduced. The system interface is composed of a cross-linkable poly(N-isopropylacrylamide)-based copolymer and regioregular poly[3-(6-methoxyhexyl)thiophene] fabricated via electrospinning and integrated into a neural probe. The coating's nanofibrous architecture offers a rapid swelling response and faster shape recovery compared to bulk hydrogels. Moreover, the smart coating becomes more conductive at physiological temperatures, which improves signal transmission efficiency and enhances its stability during chronic use. Indeed, detecting acute neuronal deep brain signals in a mouse model demonstrates that the developed probe can record high-quality signals and action potentials, favorably modulating impedance and capacitance. Evaluation of in vivo neuronal activity and biocompatibility in chronic configuration shows the successful recording of deep brain signals and a lack of substantial inflammatory response in the long-term. The development of conducting fibrous hydrogel bio-interface demonstrates its potential to overcome the limitations of current neural probes, highlighting its promising properties as a candidate for long-term, high-quality detection of neuronal activities for deep brain applications such as BMIs.

Afiliacje autorów:
Zargarian S. - IPPT PAN
Rinoldi C. - IPPT PAN
Ziai Y. - IPPT PAN
Zakrzewska A. - IPPT PAN
Fiorelli R. - inna afiliacja
Gazińska M. - inna afiliacja
Marinelli M. - inna afiliacja
Majkowska M. - inna afiliacja
Hottowy P. - inna afiliacja
Mindur B. - inna afiliacja
Czajkowski R. - inna afiliacja
Kublik E. - inna afiliacja
Nakielski P. - IPPT PAN
Lanzi M. - University of Bologna (IT)
Kaczmarek L. - inna afiliacja
Pierini F. - IPPT PAN
20p.
2.  Szwed-Georgiou A., Płociński P., Kupikowska-Stobba B., Urbaniak Mateusz M., Rusek-Wala P., Szustakiewicz K., Piszko P., Krupa A., Biernat M., Gazińska M., Kasprzak M., Nawrotek K., Pereira Mira N., Rudnicka K., Bioactive Materials for Bone Regeneration: Biomolecules and Delivery Systems, ACS BIOMATERIALS SCIENCE & ENGINEERING, ISSN: 2373-9878, DOI: 10.1021/acsbiomaterials.3c00609, Vol.9, No.9, pp.5222-5254, 2023140p.
3.  Nakielski P., Rinoldi C., Pruchniewski M., Pawłowska S., Gazińska M., Strojny B., Rybak D., Jezierska-Woźniak K., Urbanek O., Denis P., Sinderewicz E., Czelejewska W., Staszkiewicz-Chodor J., Grodzik M., Ziai Y., Barczewska M., Maksymowicz W., Pierini F., Laser-assisted fabrication of injectable nanofibrous cell carriers, Small, ISSN: 1613-6810, DOI: 10.1002/smll.202104971, Vol.18, No.2, pp.2104971-1-18, 2022

Streszczenie:
The use of injectable biomaterials for cell delivery is a rapidly expanding field which may revolutionize the medical treatments by making them less invasive. However, creating desirable cell carriers poses significant challenges to the clinical implementation of cell-based therapeutics. At the same time, no method has been developed to produce injectable microscaffolds (MSs) from electrospun materials. Here the fabrication of injectable electrospun nanofibers is reported on, which retain their fibrous structure to mimic the extracellular matrix. The laser-assisted micro-scaffold fabrication has produced tens of thousands of MSs in a short time. An efficient attachment of cells to the surface and their proliferation is observed, creating cell-populated MSs. The cytocompatibility assays proved their biocompatibility, safety, and potential as cell carriers. Ex vivo results with the use of bone and cartilage tissues proved that NaOH hydrolyzed and chitosan functionalized MSs are compatible with living tissues and readily populated with cells. Injectability studies of MSs showed a high injectability rate, while at the same time, the force needed to eject the load is no higher than 25 N. In the future, the produced MSs may be studied more in-depth as cell carriers in minimally invasive cell therapies and 3D bioprinting applications.

Afiliacje autorów:
Nakielski P. - IPPT PAN
Rinoldi C. - IPPT PAN
Pruchniewski M. - inna afiliacja
Pawłowska S. - IPPT PAN
Gazińska M. - inna afiliacja
Strojny B. - inna afiliacja
Rybak D. - IPPT PAN
Jezierska-Woźniak K. - inna afiliacja
Urbanek O. - IPPT PAN
Denis P. - IPPT PAN
Sinderewicz E. - inna afiliacja
Czelejewska W. - inna afiliacja
Staszkiewicz-Chodor J. - inna afiliacja
Grodzik M. - inna afiliacja
Ziai Y. - IPPT PAN
Barczewska M. - University of Warmia and Mazury in Olsztyn (PL)
Maksymowicz W. - University of Warmia and Mazury in Olsztyn (PL)
Pierini F. - IPPT PAN
200p.

Abstrakty konferencyjne
1.  Nakielski P., Rinoldi C., Pruchniewski M., Rybak D., Jezierska-Woźniak K., Gazińska M., Strojny B., Grodzik M., Maksymowicz W., Pierini F., Injectable nanofibrous microscaffolds, EHDAES, European Symposium on Electrohydrodynamic Atomization and Electrospinning, 2022-04-27/04-29, Napoli (IT), pp.1, 2022
2.  Nakielski P., Rinoldi C., Pruchniewski M., Rybak D., Jezierska-Woźniak K., Gazińska M., Strojny B., Grodzik M., Maksymowicz W., Pierini F., Injectable nanofibrous microscaffolds for cell and drug delivery, TERMIS-EU 2022, Tissue Engineering and Regenerative Medicine International Society European Chapter Conference 2022, 2022-06-28/07-01, Kraków (PL), pp.1, 2022

Kategoria A Plus

IPPT PAN

logo ippt            ul. Pawińskiego 5B, 02-106 Warszawa
  +48 22 826 12 81 (centrala)
  +48 22 826 98 15
 

Znajdź nas

mapka
© Instytut Podstawowych Problemów Techniki Polskiej Akademii Nauk 2025