Instytut Podstawowych Problemów Techniki
Polskiej Akademii Nauk

Partnerzy

Peter A. Smethurst


Ostatnie publikacje
1.  Rabcuka J., Smethurst P. A., Dammert K., Saker J., Aran G., Walsh G. M., Tan J. C. G., Codinach M., McTaggart K., Marks D. C., Bakker S. J. L., McMahon A., Di Angelantonio E., Roberts D. J., Błoński S., Korczyk P.M., Shirakami A., Cardigan R., Swietach P., Assessing the kinetics of oxygen-unloading from red cells using FlowScore, a flow-cytometric proxy of the functional quality of blood, eBioMedicine, ISSN: 2352-3964, DOI: 10.1016/j.ebiom.2024.105498, Vol.111, pp.105498-105498, 2025

Streszczenie:
Background
Metrics evaluating the functional quality of red blood cells (RBCs) must consider their role in oxygen delivery. Whereas oxygen-carrying capacity is routinely reported using haemoglobin assays, the rate of oxygen exchange is not measured, yet also important for tissue oxygenation. Since oxygen-unloading depends on the diffusion pathlength inside RBCs, cell geometry offers a plausible surrogate.
Methods
We related the time-constant of oxygen-unloading (τ), measured using single-cell oxygen saturation imaging, with flow-cytometric variables recorded on a haematology analyser. Experiments compared freshly-drawn RBCs with stored RBCs, wherein metabolic run-down and spherical remodelling hinder oxygen unloading.
Findings
Multivariable regression related τ to a ratio of side- and forward-scatter, referred to herein as FlowScore. FlowScore was able to distinguish, with sensitivity and specificity >80%, freshly drawn blood from blood that underwent storage-related kinetic attrition in O2-handling. Moreover, FlowScore predicted τ restoration upon biochemical rejuvenation of stored blood. Since RBC geometry and metabolic state are related, variants of FlowScore estimated [ATP] and [2,3-diphosphoglycerate]. The veracity of FlowScore was confirmed by four blood-banking systems (Australia, Canada, England, Spain). Applying FlowScore to data from the COMPARE study revealed a positive association with the time-delay from sample collection to measurement, which was verified experimentally. The LifeLines dataset revealed age, sex, and smoking among factors affecting FlowScore.
Interpretation
We establish FlowScore as a widely-accessible and cost-effective surrogate of RBC oxygen-unloading kinetics. As a metric of a cellular process that is sensitive to storage and disease, we propose FlowScore as an RBC quality marker for blood-banking and haematology.

Słowa kluczowe:
Haematology,Erythrocytes,Storage lesion,Assay,Oxygen transport,Transfusion

Afiliacje autorów:
Rabcuka J. - inna afiliacja
Smethurst P. A. - inna afiliacja
Dammert K. - inna afiliacja
Saker J. - inna afiliacja
Aran G. - inna afiliacja
Walsh G. M. - inna afiliacja
Tan J. C. G. - inna afiliacja
Codinach M. - inna afiliacja
McTaggart K. - inna afiliacja
Marks D. C. - inna afiliacja
Bakker S. J. L. - inna afiliacja
McMahon A. - inna afiliacja
Di Angelantonio E. - inna afiliacja
Roberts D. J. - inna afiliacja
Błoński S. - IPPT PAN
Korczyk P.M. - IPPT PAN
Shirakami A. - inna afiliacja
Cardigan R. - inna afiliacja
Swietach P. - inna afiliacja
140p.
2.  Rabcuka J., Błoński S., Meli A., Sowemimo-Coker S., Zaremba D., Stephenson D., Dzieciatkowska M., Nerguizian D., Cardigan R., Korczyk P.M., Smethurst P.A., D’Alessandro A., Swietach P., Metabolic reprogramming under hypoxic storage preserves faster oxygen unloading from stored red blood cells, Blood Advances, ISSN: 2473-9529, DOI: 10.1182/bloodadvances.2022007774, Vol.6, No.18, pp.5415-5428, 2022

Streszczenie:
Stored red blood cells (RBCs) incur biochemical and morphological changes, collectively termed the storage lesion. Functionally, the storage lesion manifests as slower oxygen unloading from RBCs, which may compromise the efficacy of transfusions where the clinical imperative is to rapidly boost oxygen delivery to tissues. Recent analysis of large real-world data linked longer storage with increased recipient mortality. Biochemical rejuvenation with a formulation of adenosine, inosine, and pyruvate can restore gas-handling properties, but its implementation is impractical for most clinical scenarios. We tested whether storage under hypoxia, previously shown to slow biochemical degradation, also preserves gas-handling properties of RBCs. A microfluidic chamber, designed to rapidly switch between oxygenated and anoxic superfusates, was used for single-cell oxygen saturation imaging on samples stored for up to 49 days. Aliquots were also analyzed flow cytometrically for side-scatter (a proposed proxy of O2 unloading kinetics), metabolomics, lipidomics, and redox proteomics. For benchmarking, units were biochemically rejuvenated at 4 weeks of standard storage. Hypoxic storage hastened O2 unloading in units stored to 35 days, an effect that correlated with side-scatter but was not linked to posttranslational modifications of hemoglobin. Although hypoxic storage and rejuvenation produced distinct biochemical changes, a subset of metabolites including pyruvate, sedoheptulose 1-phosphate, and 2/3 phospho-d-glycerate, was a common signature that correlated with changes in O2 unloading. Correlations between gas handling and lipidomic changes were modest. Thus, hypoxic storage of RBCs preserves key metabolic pathways and O2 exchange properties, thereby improving the functional quality of blood products and potentially influencing transfusion outcomes.

Słowa kluczowe:
hypoxia, Hemanext, erythrocyte, hemoglobin, oxidative stress, microfluidics

Afiliacje autorów:
Rabcuka J. - inna afiliacja
Błoński S. - IPPT PAN
Meli A. - inna afiliacja
Sowemimo-Coker S. - inna afiliacja
Zaremba D. - IPPT PAN
Stephenson D. - inna afiliacja
Dzieciatkowska M. - inna afiliacja
Nerguizian D. - inna afiliacja
Cardigan R. - inna afiliacja
Korczyk P.M. - IPPT PAN
Smethurst P.A. - inna afiliacja
D’Alessandro A. - inna afiliacja
Swietach P. - inna afiliacja
40p.

Kategoria A Plus

IPPT PAN

logo ippt            ul. Pawińskiego 5B, 02-106 Warszawa
  +48 22 826 12 81 (centrala)
  +48 22 826 98 15
 

Znajdź nas

mapka
© Instytut Podstawowych Problemów Techniki Polskiej Akademii Nauk 2024