Institute of Fundamental Technological Research
Polish Academy of Sciences

Partners

An-Bang Wang

National Taiwan University (TW)

Recent publications
1.  Kurniawan T., Tsai P.H., Chen S.S., Frakes D.H., Chen C.C., Wang A.B., Practical notes toward higher quality and more reliable experiments on drop and liquid surface interactions, Experiments in Fluids, ISSN: 0723-4864, DOI: 10.1007/s00348-021-03346-w, Vol.63, No.1, pp.8-1-27, 2022

Abstract:
Reliable experimental data are essential for good research. Also, the interaction of drop and liquid surface is ubiquitous and of practical importance in our lives. However, beginning researchers often face an unavoidable long learning curve due to a lack of systematic collection of failure experiences. These include somewhat trivial but also influential factors, especially in cases of low impact velocities, e.g., the feeding process into a liquid tank, the dropping into a drip chamber, and/or neglecting the initial velocity associated with the dripping drop generation in the experimental preparation processes, etc. Inconsistent experimental comparisons may arise from different methods of thin-film preparation and measurement or from nonunified parameter definition, e.g., the penetration depth of vortex rings induced by low-velocity drop impact, which makes experimental data analysis and comparison even more challenging. Here, we have accumulated some of our experience in preparing drop and liquid surface interactions including a short review of preparing thin (or very thin) target liquid film of well-defined thickness; the method to minimize the commonly neglected current underneath the target liquid; the method of generating the satellite-free drop along with the correct prediction of drop oscillation phase in the free-falling period after pinch-off, and the role of drop initial velocity, etc. These archival data are expected to shorten the learning period and facilitate benchmarking of related experiments for future users in our community.

Affiliations:
Kurniawan T. - IPPT PAN
Tsai P.H. - National Taiwan University (TW)
Chen S.S. - National Taiwan University (TW)
Frakes D.H. - National Taiwan University (TW)
Chen C.C. - National Taiwan University (TW)
Wang A.B. - National Taiwan University (TW)
2.  Tsai P., Kurniawan T., Wang A., A simple technique to achieve meniscus-free interfaces, PHYSICS OF FLUIDS, ISSN: 1070-6631, DOI: 10.1063/1.5080659, Vol.31, No.1, pp.011702-1-9, 2019

Abstract:
Liquid wetting on a container wall forms a meniscus that causes the reading uncertainty of interface measurement, which was considered as an “inevitable” interference in experiments. For minimizing the meniscus interference, the dynamic instead of the static contact angle should be focused on and θr ≤ 90° ± ε ≤ θa is the guideline to achieve a meniscus-free interface for a practical experiment, where θr, θa, and ε are the receding and advancing contact angles, and image measuring uncertainty, respectively. A simple and systematic technique to achieve the meniscus-free interface has been proposed and visualized.

Keywords:
Thermal instruments, Liquids, Fluid dynamics, Flow visualization, Capillary flows

Affiliations:
Tsai P. - National Taiwan University (TW)
Kurniawan T. - other affiliation
Wang A. - National Taiwan University (TW)
3.  Wang A., Cheng C., Lin I., Lu F., Tsai H., Lin C., Yang C., Pan P., Kuan C., Chen Y., Lin Y., Chang C., Wu Y., Kurniawan T., Lin C., Wo Andrew M., Chen L., A novel DNA selection and direct extraction process and its application in DNA recombination, Electrophoresis, ISSN: 0173-0835, DOI: 10.1002/elps.201000449, Vol.32, pp.423-430, 2011

Abstract:
In the conventional bench-top approach, the DNA recombination process is time- and effort-consuming due to laborious procedures lasting from several hours to a day. A novel DNA selection and direct extraction process has been proposed, integrated and tested on chip. The integrative microfluidic chip can perform the whole procedure of DNA recombination, including DNA digestion, gel electrophoresis, DNA extraction and insert-vector ligation within 1 h. In this high-throughput design, the manual gel cutting was replaced by an automatic processing system that performed high-quality and high-recovery efficiency in DNA extraction process. With no need of gel-dissolving reagents and manipulation, the application of selection and direct extraction process could significantly eliminate the risks from UV and EtBr and also facilitate DNA recombination. Reliable output with high success rate of cloning has been achieved with a significant reduction in operational hazards, required materials, efforts and time.

Keywords:
Chip integration, DNA recombination, DNA selection and extraction , Microfluidics

Affiliations:
Wang A. - National Taiwan University (TW)
Cheng C. - other affiliation
Lin I. - other affiliation
Lu F. - other affiliation
Tsai H. - other affiliation
Lin C. - other affiliation
Yang C. - other affiliation
Pan P. - other affiliation
Kuan C. - other affiliation
Chen Y. - other affiliation
Lin Y. - other affiliation
Chang C. - other affiliation
Wu Y. - other affiliation
Kurniawan T. - other affiliation
Lin C. - other affiliation
Wo Andrew M. - other affiliation
Chen L. - other affiliation

Category A Plus

IPPT PAN

logo ippt            Pawińskiego 5B, 02-106 Warsaw
  +48 22 826 12 81 (central)
  +48 22 826 98 15
 

Find Us

mapka
© Institute of Fundamental Technological Research Polish Academy of Sciences 2024