Recent publications
1.  Borodziński K., Filipczyński L., Nowicki A., Powałowski T., Quantitative transcutaneous measurements of blood flow in carotid artery by means of pulse and continuous wave Doppler methods, ULTRASOUND IN MEDICINE AND BIOLOGY, ISSN: 0301-5629, DOI: 10.1016/0301-5629(76)90036-3, Vol.2, No.3, pp.189-193, 1976

Abstract:
The authors present results of quantitative measurements of blood in vivo in the carotid artery of man. The Doppler pulse technique was used after being previously verified for steady state flows in tubes and for pulsating flows in a canine aorta where the electromagnetic method was also used for comparison.

An ultrasonic probe with two transducers was adapted for determination of the angle of the ultrasonic beam in relation to the vessel allowing the measurement of the vessel diameter which was also determined by means of the ultrasonographic B-mode technique.

By means of the Doppler pulse method profiles of the blood velocity in the carotid artery were determined as a function of time.

The continous wave Doppler technique together with the zero-crossing system and spectral analysis were also used for making measurements.

The flow velocity and the shape of the flow curve with time obtained with the above techniques showed good agreement. The measured flow rate in the carotid artery amounted to QM = 1.61/min (maximum instantaneous value) and Q0 - 0.531/min (mean time value).

Affiliations:
Borodziński K. - other affiliation
Filipczyński L. - IPPT PAN
Nowicki A. - IPPT PAN
Powałowski T. - IPPT PAN
2.  Powałowski T., Borodziński K., Nowicki A., Ocena pomiaru przepływu ciągłą metodą dopplerowską, Prace IPPT - IFTR Reports, ISSN: 2299-3657, No.72, pp.11-22, 1974
3.  Nowicki A., Borodziński K., Powałowski T., Impulsowy dopplerowski miernik przepływu krwi, Prace IPPT - IFTR Reports, ISSN: 2299-3657, No.72, pp.1-9, 1974
4.  Borodziński K., Filipczyński L., Nowicki A., Powałowski T., Badania prędkości przepływu ultradźwiękową metodą wykorzystującą zjawisko Dopplera, Prace IPPT - IFTR Reports, ISSN: 2299-3657, No.40, pp.1-16, 1972

Patents
Filing No./Date
Filing Publication
Autors
Title
Protection Area, Applicant Name
Patent Number
Date of Grant
pdf
179156
1975-03-28

1976-10-23
Filipczyński L., Nowicki A., Borodziński K.
Pulsed ultrasonic flow meter and the fluid velocity profile in particular blood flowing in the blood vessels
PL, Instytut Podstawowych Problemów Techniki PAN
99449

1978-11-15



175318
1974-11-04

1976-12-04
Filipczyński L., Etienne J., Borodziński K.
An ultrasound device for obstetric examinations using the Doppler effect
PL, Instytut Podstawowych Problemów Techniki PAN
97328

1979-07-30



162550
1973-05-15

1975-04-01
Borodziński K., Etienne J., Nowicki A., Powałowski T.
Ultrasonic method and apparatus for testing the fetal heart rate using the Doppler
PL, Instytut Podstawowych Problemów Techniki PAN