1. |
Wojtiuk E.♦, Radziejewska J., Marczak M.♦, The influence of abrasive finishing conditions on the surface texture of Inconel 939 elements made using the 3D printing LPBF method,
PRZEGLĄD SPAWALNICTWA, ISSN: 0033-2364, DOI: 10.26628/simp.wtr.v96.1180.34-40, Vol.96, pp.34-40, 2024Abstract: The article presents research on finishing treatment applied to components made of Inconel through 3D printing by Laser Powder Bed Fusion method. Vibration-abrasive machining was carried out using a supporting fluid and various shapes of abrasive. The effects of the processing conditions were analysed based on the surface roughness of the samples and mass loss. The obtained collective results were subjected to comparative analysis with the effects of vibratory-abrasive processing without the use of a processing fluid, as presented in the article. The research has shown that using vibration-abrasive processing, it is possible to reduce the height of surface irregularities by more than three times after four hours of treatment. The intensity of processing was the highest in the first hour of the process. The lowest roughness heights Ra = 1.8 μm were obtained using ceramic balls in the presence of a supporting fluid. Keywords: vibration-abrasive processing, IN939, roughness, additive manufacturing, 3D printing post-processing Affiliations:
Wojtiuk E. | - | other affiliation | Radziejewska J. | - | IPPT PAN | Marczak M. | - | Institute of Cardiology (PL) |
| |
2. |
Lipczyńska M.♦, Michałowska I.♦, Werys K.♦, Marczak M.♦, Lewandowski M., Lipiec P.♦, Kasprzak J.♦, Klisiewicz A.♦, Szymański P.♦, Płońska-Gościniak E.♦, Artefakty nieinwazyjnego obrazowania serca,
Kardiologia Polska, ISSN: 0022-9032, DOI: 10.5603/kp.2015.0206, Vol.73, pp.60-70, 2015Abstract: Nieinwazyjne metody obrazowania serca są nieodłączną częścią współczesnej diagnostyki kardiologicznej. Jakość obrazowania niezależnie od użytej techniki stanowi ważny element interpretacji wyniku. Znajomość najczęstszych artefaktów echokardiografii, tomografii rentgenowskiej (CT, X-ray computed tomography) i badania serca metodą rezonansu magnetycznego (CMRI, cardiac magnetic resonance imaging) oraz sposobu ich uniknięcia jest istotna w codziennej pracy. Keywords: obrazowanie medyczne, USG, CT, CMRI Affiliations:
Lipczyńska M. | - | other affiliation | Michałowska I. | - | other affiliation | Werys K. | - | Warsaw University of Technology (PL) | Marczak M. | - | Institute of Cardiology (PL) | Lewandowski M. | - | IPPT PAN | Lipiec P. | - | other affiliation | Kasprzak J. | - | other affiliation | Klisiewicz A. | - | other affiliation | Szymański P. | - | other affiliation | Płońska-Gościniak E. | - | other affiliation |
| |
3. |
Guzik J.♦, Wojtyniak M.♦, Olszowski S.♦, Marczak M.♦, Ranachowski Z., Investigation of acoustic emission signal generated in the friction pair lubricated with oils containing various lubricity additives,
ENGINEERING TRANSACTIONS (ROZPRAWY INŻYNIERSKIE), ISSN: 0867-888X, Vol.54, pp.159-166, 2006 | |
4. |
Bejger A.♦, Guzik J.♦, Marczak M.♦, Olszowski S.♦, Ranachowski Z., Diagnostics of the fuel injectors of medium speed diesel engine with application of acoustic signal,
THE ARCHIVES OF AUTOMOTIVE ENGINEERING - ARCHIWUM MOTORYZACJI, ISSN: 1234-754X, Vol.3, No.3, pp.199-207, 2005 | |